How Bosch inputs are displayed in Security Center SaaS
2025-06-17Last updated
Before configuring the inputs of a Bosch panel, you must understand how its contact types are displayed in Genetec™ Configuraton and Genetec™ Operation.
| Bosch panel | Single EOL resistor - Security Center SaaS | Dual EOL resistor - Security Center SaaS |
|---|---|---|
| Normal | Normal | - |
| Open | Trouble (Open) | - |
| Short | Active | - |
| RX2 | - | - |
Note:
Bosch 5.1.0 intrusion panels don’t
support the Normally open contact type configuration for input circuits with a Dual
EOL (End Of Line) resistor. If a panel uses this configuration, it displays the same
return states as a panel configured with a Normally closed contact type.
| Bosch panel | Single EOL resistor - Security Center SaaS | Dual EOL resistor - Security Center SaaS |
|---|---|---|
| Normal | Normal | Normal |
| Open | Active | Trouble (Open) |
| Short | Trouble (Short) | Trouble (Short) |
| RX2 | - | Active |