To configure a manual trigger for an output on a Bosch intrusion panel, you must create
a virtual output by setting the source of a point to Output in Bosch
Remote Programming Software (RPS).
Before you begin
Configure your point and area profiles in Bosch RPS. For more information, see your
Bosch documentation.
What you should know
Bosch RPS refers to inputs as points.
Procedure
-
Open Bosch RPS and select an intrusion panel.
-
Configure a point as an output:
-
Click .
-
Select a point with an unassigned source.
-
Click the Source cell of the point, select
Output, then click OK.
-
Click the Profile cell of the point, select a point profile,
then click OK.
-
Click the Area cell of the point, select an area profile,
then click OK.
The system creates the virtual output.
-
Click Save.
-
Click the Synchronization (
) button.
- Bosch RPS pushed the point to the intrusion panel.
- An input and output are added to Security Center SaaS to represent the point.