Enabling communication with Security Center SaaS using the B426 Ethernet module
2026-07-14Last updated
After you’ve configured your Bosch intrusion panel, you can enable communication with Security Center SaaS using a B426 Ethernet module.
Before you begin
What you should know
- Using a B426 Ethernet module is optional.
- The B426 Ethernet module requires Transport Layer Security (TLS) 1.2.
- Bosch B series panels support Bosch's Mode 2 arming mode.
Important:
Connecting to the intrusion panel using an external B426 Ethernet
module on Bosch B or Bosch B/G series panels might prevent the integration from functioning
correctly. This is because the Bosch panel sometimes causes data overflow errors on the B426
module.
Best Practice:
Connect to the intrusion panel using an on-board Ethernet module that
uses asynchronous communication.
Procedure
-
On the Basic Network Settings page of the module's web page, do
the following:
-
On the Encryption and Security Settings page, do the
following:
- From the Encryption Enable drop-down, select No.
- From the Web and Automation Security drop-down, select Mode 2: Enable as the automation mode of operation you configured for the panel.
- Click OK.
-
On the Maintenance page, do the following:
- Click Save and Execute.